“never plug extension cords into extension cords” is probably the most common piece of electrical related advice I’ve ever heard. But if you have, say, 2 x 2m long extension cords, and you plug one into the other, why is that considered a lot more unsafe than just using a single 4 or 5 meter cord?

Does it just boil down to that extra connection creating another opportunity for the prongs to slip out and cause a spark or short circuit? Or is there something else happening there?

For that matter - why aren’t super long extension cords (50 or more meters) considered unsafe? Does that also just come down to a matter of only having 2 connections versus 4 or more on a daisy chained cord?

Followup stupid question: is whatever causes piggybacked extension cords to be considered unsafe actually that dangerous, or is it the sort of thing that gets parroted around and misconstrued/blown out of proportion? On a scale from “smoking 20 packs of cigarettes a day” to “stubbing your toe on a really heavy piece of furniture”, how dangerous would you subjectively rate daisy chaining extension cords, assuming it was only 1 hop (2 extension cords, no more), and was kept under 5 or 10 metres?

I’m sure there’s probably somebody bashing their head against a wall at these questions, but I’m not trying to be ignorant, I’m just curious. Thank you for tolerating my stupid questions

  • Lemminnewbie2@lemm.ee
    link
    fedilink
    arrow-up
    3
    ·
    2 days ago

    It’s going to be down to the gauge of the wire and if it’s rated for hard usage. There would be no difference if the 4m cable was the same gauge and insulation type as two 2m cables connected by cord and plug. You couldn’t say how dangerous it is specifically without calculating the load, wire ampacity, ambient temperature, insulation type, distance, and on and on so it’s general advice to prevent fires from overheating wires.

    • Em Adespoton@lemmy.ca
      link
      fedilink
      arrow-up
      1
      ·
      1 day ago

      There is a difference, actually. The cords are the same gauge, but with two shorter ones, the wire is broken up in the middle to run through a plug and socket. This whole assembly causes impedance and can heat up.

      Not as much of an issue if each plug and socket has a fuse, but if they don’t, those are the heat and arc points.